description: Manual of the ipmicli command-line client of the IPMI Java Client - subcommands, connection options, passwords and BMC key, text and JSON output, the System Event Log, the interactive Serial over LAN console, raw requests, exit codes, and the ipmitool equivalents.
date_published: 2026-10-14
date_modified: 2026-10-14
canonical_url: https://metricshub.org/ipmi-java/cli.html
---

# Command-Line Client

On this Page

- [Synopsis](#synopsis)
- [Subcommands](#subcommands)
- [Connection options](#connection-options) 
  
    - [Default privilege per subcommand](#default-privilege-per-subcommand)
- [Passwords and BMC key](#passwords-and-bmc-key)
- [Output](#output) 
  
    - [probe](#probe)
    - [info](#info)
    - [chassis and power status](#chassis-and-power-status)
    - [power actions and identify](#power-actions-and-identify)
    - [sensors](#sensors)
    - [fru](#fru)
    - [sel](#sel)
    - [raw](#raw)
- [Interactive SOL console](#interactive-sol-console)
- [Exit codes](#exit-codes)
- [Examples](#examples)
- [ipmitool equivalents](#ipmitool-equivalents)

Every release ships a self-contained executable jar that bundles the library and a command-line client, **`ipmicli`**. This page is its manual. Install it with one command (Java 8 or later is required):

#### Linux / macOS

```shell-session
$ curl -fsSL https://metricshub.org/ipmi-java/get | sh
```

#### Windows (PowerShell)

```powershell
irm https://metricshub.org/ipmi-java/get.ps1 | iex
```

The installer verifies the checksum of the jar and puts an `ipmicli` launcher on the `PATH`; see [Installation](installation.html#command-line-client) to inspect the script first, pin a version or change the directories.

```text
ipmicli [options] <subcommand> [subcommand options]
```

Without the installer, download `ipmi-java-2.0.00-standalone.jar` from the [latest release](https://github.com/metricshub/ipmi-java/releases/latest) and run it with `java -jar ipmi-java-2.0.00-standalone.jar` wherever this page says `ipmicli`. The jar needs no other file: the library has no dependency.

The CLI is a thin layer over the [IpmiClient](index.html#quick-start) API: every subcommand is one operation of the client, with the same defaults, the same [session handling](timeouts-and-errors.html#session-recovery) and the same failures, reported as exit codes. It is meant to feel familiar to `ipmitool` users: see the [ipmitool equivalents](#ipmitool-equivalents).

## Synopsis

```text
ipmicli -h <host> probe [--json]
ipmicli -h <host> -u <user> [options] info [--json]
ipmicli -h <host> -u <user> [options] chassis [--json]
ipmicli -h <host> -u <user> [options] power status | on | off | cycle | reset | soft | diag
ipmicli -h <host> -u <user> [options] identify [<seconds> | force | off]
ipmicli -h <host> -u <user> [options] sensors [--type <type>,...] [--name <glob>,...] [--long] [--json]
ipmicli -h <host> -u <user> [options] fru [<id>...] [--json]
ipmicli -h <host> -u <user> [options] sel [--since <id>] [--json]
ipmicli -h <host> -u <user> [options] sol [--escape <char> | --no-escape]
ipmicli -h <host> -u <user> [options] raw <netfn> <command> [<data byte>...] [--json]
ipmicli --help | --version
```

The options before the subcommand are the [connection options](#connection-options); the options after it belong to the subcommand, in any order with its arguments. `--help` prints the usage summary, `--version` the version of the build.

## Subcommands

| Subcommand | Library operation | Description |
| --- | --- | --- |
| `probe` | `capabilities()` | What the BMC offers **before any login**: IPMI 2.0 support, whether a BMC key (Kg) is required, the anonymous and null-user logins, per-message and user-level authentication, and the cipher suites with their algorithms, whether the library implements them, and the one the CLI would choose. Needs no credentials: the first thing to run when a login fails. |
| `info` | `deviceId()` | The identity of the BMC: manufacturer and product IDs, firmware revision, IPMI version, the functions it provides ([Device ID](device-id.html)). |
| `chassis` | `chassisStatus()` | The power state, the power restore policy, the last power event, the faults (power, cooling, drive), interlock, overload, intrusion, front panel lockout, and the identify state. |
| `power status` | `chassisStatus()` | Prints `on` or `off`. |
| `power on`, `off`, `cycle`, `reset`, `soft`, `diag` | `chassisControl()` | Powers the system on; off at once; off then on; resets it; asks the operating system to shut down (ACPI); pulses a diagnostic interrupt (NMI). Prints nothing: the exit code says whether the BMC accepted the command, which it carries out afterwards. |
| `identify`, `identify <seconds>`, `identify force`, `identify off` | `chassisIdentify()` | Blinks the identify LED of the chassis for 15 seconds, or for `<seconds>` (1 to 255), or until `identify off` with `force` (not every BMC supports it). Prints nothing. |
| `sensors` | `sensors()` | One line per sensor with its reading, unit and status. `--type` and `--name` select the sensors **before** they are read (fewer round trips on a slow BMC); `--long` adds the sensor number, the entity, the six thresholds and the problem of a sensor without reading. |
| `fru` | `frus()` | The FRU inventory, one block per FRU with the fields of its chassis, board and product areas; `<id>...` reads only these FRU IDs. |
| `sel` | `sel()` | The System Event Log, one line per entry with its time, the sensor that reported it, the event and its direction; `--since <id>` reads only the entries after the given record ID. |
| `sol` | `sol().open()` | An interactive [Serial over LAN console](#interactive-sol-console) on the serial port of the server. |
| `raw` | `raw(netFn, command).data(...).execute()` | Sends any request, like `ipmitool raw`: the network function, the command and the data bytes in hexadecimal, `0x` optional (`06`, `0x06` and `6` are the same byte). Prints the response data in hexadecimal, 16 bytes per line. Extension and OEM network functions are accepted (`raw 0x2c 0x01 0xdc 0x01`, Get DCMI Capabilities Info). |

`sensors` lists the sensor types to pass to `--type` as they are named in [SensorType](apidocs/org/metricshub/ipmi/core/coding/commands/sdr/record/SensorType.html) (`Temperature`, `Voltage`, `Fan`, `PowerSupply`, `Processor`, `Memory`…), case-insensitively; `--name` takes globs where `*` matches any characters and `?` one, case-insensitively, and either option can be repeated or given a comma-separated list.

## Connection options

| Option | Description |
| --- | --- |
| `-h, --hostname <host>` | BMC host name or IP address (IPv4 or IPv6). Required. |
| `-u, --username <user>` | User name. Required, except for `probe`. An empty string (`-u ""`) is the null user (anonymous login). |
| `-p, --password <password>` | Password. Command-line arguments may be visible to other local processes: avoid in automation. |
| `-pf, --password-file <file>` | Read the password from a UTF-8 file (preferred for automation, see [below](#passwords-and-bmc-key)). |
| `-k, --bmc-key <hex>` | BMC key (Kg) of a two-key login, in hexadecimal (`0x` optional), at most 20 bytes. |
| `-kf, --bmc-key-file <file>` | Read the hexadecimal BMC key from a file. |
| `-P, --port <port>` | UDP port of the BMC. Default: 623. |
| `-L, --privilege <level>` | `user`, `operator` or `administrator` (case-insensitive). Default: the lowest level the subcommand needs (see [below](#default-privilege-per-subcommand)). |
| `-C, --cipher-suite <id>[,<id>...]` | One ID: use exactly this cipher suite, without discovery. Several: the preference order among the suites the BMC offers. Default: `17,3,8,16,2,7`. Suites without integrity (0, 1, 6, 15) are refused: their replies could be forged. |
| `-t, --timeout <ms>` | Deadline of the subcommand, in milliseconds. Default: 120000. For `sol`, it bounds the session setup and the payload activation only. |
| `--message-timeout <ms>` | Per-message timeout. Default: 5000. |
| `--retries <n>` | Resends of a message that got no reply. Default: 3. |
| `-v, --verbose` | Print to stderr the address, the user and privilege, the cipher suite preference, and the time of each operation. Never prints a secret. |
| `--help` | Print the usage summary. |
| `--version` | Print the version of the build. |

The two password options are mutually exclusive, and so are the two BMC key options. Every option also takes the `--option=value` form. `-p` is the password and `-P` the port, as in the other MetricsHub command-line clients; `ipmitool` uses the reverse (see the [equivalents](#ipmitool-equivalents)).

### Default privilege per subcommand

A session asks for its maximum privilege level at login and is raised to it right after, and a BMC refuses the login, or the raise, when the account is not allowed that level. So the CLI asks for the **least** privilege that works (unlike `ipmitool`, which asks for Administrator and fails with read-only accounts unless given `-L USER`):

| Subcommands | Default `-L` |
| --- | --- |
| `info`, `chassis`, `power status`, `sensors`, `fru`, `sel` | `user` |
| `power on`, `off`, `cycle`, `reset`, `soft`, `diag`, `identify` | `operator` |
| `sol`, `raw` | `administrator` |

A BMC that refuses a command at the session's level answers `D4h`: the CLI exits with 77 and says which higher `-L` to use (at the Administrator level, that the BMC restricts the command). Serial over LAN is the usual case: most BMCs activate the SOL payload at the Administrator level only, some at the User level. A raw request can be anything, so `raw` asks for Administrator, like `ipmitool`: give `-L user` to send a read with a read-only account.

## Passwords and BMC key

If neither `-p` nor `-pf` is given (and the subcommand is not `probe`), the CLI asks the password on the interactive console, without echo. There is no console when the standard input or output is redirected (`| jq`, `> out.txt`): such runs must use `--password-file` (or, less securely, `--password`).

A password file is decoded as UTF-8 and **exactly one** final LF, CRLF or CR is removed; every other byte, spaces and earlier line endings included, is part of the password. The same rule applies to the BMC key file, which holds the key in hexadecimal. A password or key longer than the 20 bytes a BMC stores is refused before anything is sent.

Secrets are never printed: not in the usage errors, not with `--verbose`, not in the failure messages. The CLI blanks the password argument it was given and wipes its copies of the password and of the key when it ends.

## Output

Diagnostics go **only to stderr**, so stdout can always be piped or parsed. The text output is meant for humans and is stable enough for `grep`; `--json` prints UTF-8 [JSON Lines](https://jsonlines.org/): one object per sensor, FRU or SEL entry, one object for `probe`, `info`, `chassis` and `raw`. Absent values (a reading the sensor does not have, a threshold the record does not set, an empty FRU field) are omitted from the JSON objects, never printed as `0`.

The output below was captured on a Lenovo RD350 (serial numbers masked), with `ipmicli -h bmc.example.com -u monitor -pf pw.txt ...`.

### `probe`

```text
$ ipmicli -h bmc.example.com probe
IPMI 2.0                    supported
BMC key (Kg)                not required
Anonymous login             disabled
Null user names             disabled
Non-null user names         enabled
Per-message authentication  enabled
User-level authentication   enabled
Cipher suites
  ID  Authentication    Integrity        Confidentiality  Library
  3   RAKP-HMAC-SHA1    HMAC-SHA1-96     AES-CBC-128      supported
  17  RAKP-HMAC-SHA256  HMAC-SHA256-128  AES-CBC-128      supported
Chosen cipher suite         17
```

The last line is the suite a login with the same `-C` option would use: the first suite of the preference that the BMC offers, or the single suite of a one-ID `-C`, which is used without discovery. When that suite is one the library does not implement, or one the BMC does not offer, the line says so and that the login would fail; `none` means a login would fail with *offers none of the cipher suites* ([Troubleshooting](troubleshooting.html#ipmiclientexception-3a-the-bmc-offers-none-of-the-cipher-suites)). `--json` prints one object with the same fields and the suites as an array:

```json
{"ipmi20":true,"bmcKeyRequired":false,"anonymousLogin":false,"nullUserNames":false,"nonNullUserNames":true,"perMessageAuthentication":true,"userLevelAuthentication":true,"cipherSuites":[{"id":3,"authentication":"RAKP-HMAC-SHA1","integrity":"HMAC-SHA1-96","confidentiality":"AES-CBC-128","supported":true},{"id":17,"authentication":"RAKP-HMAC-SHA256","integrity":"HMAC-SHA256-128","confidentiality":"AES-CBC-128","supported":true}],"chosenCipherSuite":17}
```

### `info`

```text
$ ipmicli -h bmc.example.com -u monitor -pf pw.txt info
Device ID                   32
Device revision             1
Firmware revision           5.38
IPMI version                2.0
Manufacturer ID             19046
Product ID                  502
Device available            yes
Provides device SDRs        no
Functions                   SENSOR_DEVICE, SDR_REPOSITORY_DEVICE, SEL_DEVICE, FRU_INVENTORY_DEVICE, IPMB_EVENT_RECEIVER, IPMB_EVENT_GENERATOR, CHASSIS_DEVICE
Aux firmware revision       b2010000
```

The values are those of [DeviceId](device-id.html): the manufacturer ID is the IANA enterprise number of the vendor (19046 is Lenovo), the firmware revision is printed as `ipmitool` prints it, the functions are the [DeviceFunction](apidocs/org/metricshub/ipmi/client/DeviceFunction.html) names (`none` when the BMC flags none), and the `Aux firmware revision` line (four bytes in hexadecimal, vendor-defined) is only printed by a BMC that sends it.

```json
{"id":32,"revision":1,"firmwareRevision":"5.38","ipmiVersion":"2.0","manufacturerId":19046,"productId":502,"available":true,"providesDeviceSdrs":false,"functions":["SENSOR_DEVICE","SDR_REPOSITORY_DEVICE","SEL_DEVICE","FRU_INVENTORY_DEVICE","IPMB_EVENT_RECEIVER","IPMB_EVENT_GENERATOR","CHASSIS_DEVICE"],"auxiliaryFirmwareRevision":"b2010000"}
```

### `chassis` and `power status`

```text
$ ipmicli -h bmc.example.com -u monitor -pf pw.txt chassis
Power                       on
Power restore policy        PowerRestored
Last power events           AC_FAILED
Power fault                 no
Power overload              no
Interlock                   no
Power control fault         no
Cooling fault               no
Drive fault                 no
Intrusion                   no
Front panel lockout         no
Identify                    Off
```

The values are those of [ChassisStatus](chassis-status.html): the power restore policy is `PoweredOff`, `PowerRestored`, `PoweredUp` or `Unknown`, the last power events are `AC_FAILED`, `POWER_OVERLOAD`, `INTERLOCK`, `POWER_FAULT` and `IPMI_COMMAND` (`none` when the BMC reports none), and the `Identify` line is only printed by a BMC that reports the identify state.

```json
{"powerOn":true,"powerRestorePolicy":"PowerRestored","lastPowerEvents":["AC_FAILED"],"powerFault":false,"powerOverload":false,"interlock":false,"powerControlFault":false,"coolingFault":false,"driveFault":false,"intrusion":false,"frontPanelLockout":false,"identifyState":"Off"}
```

`power status` prints just `on` or `off`.

### `power` actions and `identify`

```text
$ ipmicli -h bmc.example.com -u operator -pf pw.txt power off; echo $?
0
$ ipmicli -h bmc.example.com -u operator -pf pw.txt power status
off
```

A power action and `identify` print nothing: the exit code is 0 once the BMC has accepted the command. The BMC carries it out afterwards (a power off takes a few seconds, a `soft` shutdown as long as the operating system needs): `power status` shows the result. The actions map to the [PowerCommand](chassis-status.html#controlling-the-power) of the library: `on` is `PowerUp`, `off` is `PowerDown` (immediate, no operating system shutdown), `cycle` is `PowerCycle` (off for at least a second, then on), `reset` is `HardReset`, `soft` is `SoftShutdown` and `diag` is `DiagnosticInterrupt`. `cycle` of a system that is off is refused by the client before anything is sent (exit code 70: some BMCs would power the system up), `reset` of a system that is off by most BMCs with `D5h` (exit code 70); `cycle`, `soft` and `diag` are optional in the specification, and a BMC that does not implement them answers `CCh`. An action is sent once, never again when its reply is lost (the BMC may have carried it out): a lost reply exits with 124, and `power status` tells what the BMC did.

`identify` blinks the identify LED for 15 seconds, `identify 60` for a minute (1 to 255), and `identify force` until `identify off`, on the BMCs that implement the “force identify on” option (the others answer `CCh`). `chassis` shows the identify state on the BMCs that report it.

### `sensors`

```text
$ ipmicli -h bmc.example.com -u monitor -pf pw.txt sensors
Name            Type                   Reading  Unit      Status
Ambient Temp    Temperature            19       DegreesC  ok
CPU1 DTS        Temperature            -42      DegreesC  ok
Exhaust Temp    Temperature            22       DegreesC  ok
Host Power      PowerUnit                                 ok
System Power    Current                88       Watts     ok
Fan 1           Fan                    6700     Rpm       ok
HDD             DriveBay                                  unavailable
PSU Redundancy  PowerSupply                               Fully Redundant
System 3.3V     Voltage                3.38     Volts     ok
PSU1 Present    PowerSupply                               Presence detected
```

(An excerpt: the Lenovo card has 49 sensors.) The columns are aligned on their widest value, two spaces apart. The `Reading` is the converted reading of a threshold sensor, rounded to three decimals, in the `Unit` of its record; a discrete sensor has no reading. `Status` is the [status()](sensors.html#the-sensor-object) of a threshold sensor against its thresholds (`ok`, `non-critical`, `critical`, `non-recoverable`), the asserted states of a discrete sensor (`Presence detected`, `Fully Redundant`…), or `unavailable` when the BMC reports no valid reading (a sensor that is not scanned, not present, or whose reading the BMC refused).

`--long` adds the sensor number, the entity, the six thresholds (lower and upper non-recoverable, critical and non-critical) and, for a sensor without reading, the reason:

```text
$ ipmicli -h bmc.example.com -u monitor -pf pw.txt sensors --type temperature --long
Name          Number  Type         Entity           Reading  Unit      Status  LNR  LC  LNC  UNC  UC  UNR  Problem
Ambient Temp  1       Temperature  AirInlet 1       19       DegreesC  ok           3   8    37   39
CPU1 DTS      2       Temperature  Processor 1      -42      DegreesC  ok
CPU2 DTS      3       Temperature  Processor 2      -46      DegreesC  ok
Exhaust Temp  9       Temperature  SystemChassis 1  22       DegreesC  ok
```

With `--json`, one object per sensor, with the fields of [Sensor](sensors.html#the-sensor-object) (`reading` and `rawReading` only when the reading is valid, the thresholds only when the record sets them, `problem` only when there is one):

```text
$ ipmicli -h bmc.example.com -u monitor -pf pw.txt sensors --type Fan --name 'Fan 1' --json
{"name":"Fan 1","number":122,"type":"Fan","entity":"Fan","entityInstance":1,"unit":"Rpm","reading":6600.0,"rawReading":66,"status":"OK","states":[],"lowerCritical":1600.0}
```

An SDR record the library cannot decode is reported on stderr (`ipmicli: SDR record 0006h (type 0Bh): ...`) and the other sensors are printed: see [Sensors or FRUs are missing](troubleshooting.html#sensors-or-frus-are-missing).

### `fru`

```text
$ ipmicli -h bmc.example.com -u monitor -pf pw.txt fru
FRU 0: MotherBoard FRU (SystemBoard 1)
  Chassis type               RackMountChassis
  Board manufacturer         LENOVO
  Board product              RD350-RD450
  Board serial number        8SSB20A05892R1SH4AY0000
  Board part number          SB20A05892
  Board mfg date             2014-10-31T04:59:00Z
  Board custom 5             00:8C:FA:00:00:00
  Product manufacturer       LENOVO
  Product name               RD350
  Product part/model number  00000000000001
  Product version            70D60001EA
  Product serial number      S4M00000

FRU 3: MidPlane FRU (OtherSystemBoard 1)

FRU 17: PSU1 FRU (SystemInternalExpansionBoard 2)
  Product manufacturer       LITEON
  Product name               PS-2451-6L-LF
  Product serial number      003W
ipmicli: FRU 3: Cannot read FRU 3: ReadFruData failed: Requested Sensor, data, or record not present. (completion code CBh)
```

(An excerpt.) One block per FRU, headed by its ID, its name and its entity from the SDR locator record, then the fields of its chassis, board and product areas that are not empty (the custom fields of an area numbered as the area lists them, a binary one in hexadecimal). The board manufacturing date is UTC, ISO-8601. A FRU the BMC cannot read completely is reported on stderr with the fields read so far, and `fru` exits with 1 once every FRU is printed; a FRU that is declared but absent (an empty power supply bay, FRU 3 above) is the usual case ([Troubleshooting](troubleshooting.html#sensors-or-frus-are-missing)).

`fru 0 17` reads only these FRUs; an ID that no locator record declares exits with 66 (`ipmicli: no such FRU 9`). `--json` prints one object per FRU, with the summary fields of [Fru](fru-inventory.html) (`manufacturer`, `model`, `serialNumber`, `partNumber`) and one nested object per area:

```json
{"id":17,"name":"PSU1 FRU","entity":"SystemInternalExpansionBoard","entityInstance":2,"manufacturer":"LITEON","model":"PS-2451-6L-LF","serialNumber":"003W","product":{"manufacturerName":"LITEON","productName":"PS-2451-6L-LF","serialNumber":"003W"},"complete":true}
```

An incomplete FRU has `"complete":false` and a `problems` array.

### `sel`

```text
$ ipmicli -h bmc.example.com -u monitor -pf pw.txt sel
ID   Time                  Type                  Sensor  Event                                          Direction
1    2024-05-15T09:15:25Z  EventLoggingDisabled  254     Log area reset/cleared                         assertion
2    2024-05-15T09:16:11Z  OemTimestamped                OEM data 02 01 05 00 00 00
3    2024-05-15T09:16:11Z  OemTimestamped                OEM data 02 08 05 00 00 00
5    2024-05-15T09:23:27Z  PowerUnit             100     Power off/down                                 assertion
6    2024-05-15T09:23:34Z  PowerUnit             100     Power off/down                                 deassertion
7    2024-05-15T09:24:15Z  VersionChange         0       Firmware or software incompatibility detected  assertion
640  pre-init 315532807s   PowerSupply           219     Presence detected                              assertion
643  pre-init 315532815s   PowerSupply           156     Fully Redundant                                assertion
```

(An excerpt: the Lenovo card has 643 entries, 358 of them OEM records.) One line per entry of the [System Event Log](system-event-log.html), in the order of the log: the record ID, the time (UTC, ISO-8601; `pre-init <seconds>` for an event logged before the BMC had the time, like the `Pre-Init` of `ipmitool`; empty for an OEM entry without timestamp), the sensor type of a system event or the record type of an OEM one, the sensor number, the event in the wording of `ipmiutil` (of `ipmitool` for the few events `ipmiutil` does not name) or the OEM bytes, and `assertion` or `deassertion`. The times are UTC whatever the BMC keeps (it reports the offset of a local SEL time with Get SEL Time UTC Offset). `-v` adds to stderr what Get SEL Info says of the log: its number of entries, the time of the last addition and erase, and that offset.

`--since <id>` prints only the entries after the given record ID, the ID of the last entry of a previous run (the whole log when the BMC does not hold that entry any more, as after a clear; a log cleared and filled up to that ID again goes unnoticed: the `lastErase` time of `-v` tells); the header alone means no new entry. `--json` prints one object per entry with the fields of [SelEntry](system-event-log.html#the-selentry-object): `timestamp` only when it is a date, `preInitSeconds` only for a pre-init one, the system event fields (`sensorType`, `sensorNumber`, `generatorId`, `eventType`, `event`, `direction`, `eventData` in hexadecimal) only for a system event, `manufacturerId` and `oemData` only for an OEM entry:

```text
$ ipmicli -h bmc.example.com -u monitor -pf pw.txt sel --since 5 --json
{"id":6,"type":"System","timestamp":"2024-05-15T09:23:34Z","sensorType":"PowerUnit","sensorNumber":100,"generatorId":32,"eventType":111,"event":"PowerOffOrDown","description":"Power off/down","direction":"Deassertion","eventData":"00ffff"}
{"id":7,"type":"System","timestamp":"2024-05-15T09:24:15Z","sensorType":"VersionChange","sensorNumber":0,"generatorId":1,"eventType":111,"event":"FirmwareOrSoftwareIncompatibilityDetected","description":"Firmware or software incompatibility detected","direction":"Assertion","eventData":"830800"}
{"id":8,"type":"OemTimestamped","timestamp":"2024-05-15T09:29:39Z","description":"OEM data 02 01 05 05 00 00","manufacturerId":19046,"oemData":"020105050000"}
```

The sensor names are not resolved: join `sensorNumber` with the `number` of `sensors --json` when you need them (`ipmitool sel elist` walks the SDR repository for that, which takes as long as `sensors` on a slow BMC).

### `raw`

```text
$ ipmicli -h bmc.example.com -u admin -pf pw.txt raw 0x2c 0x01 0xdc 0x01
dc 01 05 02 00 01 07
$ ipmicli -h bmc.example.com -u admin -pf pw.txt raw 0x06 0x01
20 01 05 38 02 bf 66 4a 00 f6 01 b2 01 00 00
```

The response data, after the completion code, in hexadecimal: 16 bytes per line, nothing for a reply without data. The first request is Get DCMI Capabilities Info (Group Extension network function `2Ch`, whose first data byte is the defining body, `DCh` for DCMI): the reply says DCMI 1.5. The second is Get Device ID, the command behind `info`.

Every byte is hexadecimal, `0x` or not: `10` is `10h`, where `ipmitool` reads `10` as decimal and `010` as octal. The network function must be one of a request: an even byte from `00` to `3e` (the odd ones are those of the responses, IPMI 2.0 section 5.1), the standard ones as well as Transport (`0c`), Group Extension (`2c`), OEM/Group (`2e`) and the controller-specific OEM ones (`30` to `3e`). An error completion code is printed on stderr with the exit code 70 (77 with the `-L` hint for `D4h`), after the data the BMC may have sent with it; it is not retried, a busy `c0` or a `c3` included. Like any message, the request is sent again when its reply is lost (`--retries 0` sends it once): a power command is better sent with `power`, which has the safeguards. `--json` prints one object, with the completion code as a number and the data in hexadecimal (omitted when empty), also for an error completion code:

```json
{"completionCode":0,"data":"dc010502000107"}
```

## Interactive SOL console

```bash
ipmicli -h bmc.example.com -u admin -pf pw.txt sol
```

`sol` activates the Serial over LAN payload and bridges it with the terminal until the console is closed. The bytes of the BMC go to stdout unmodified, so the local terminal interprets the escape sequences of the remote console; the typed bytes go to the BMC.

- **Escape sequences**, recognized at the start of a line, as with `ssh` and `ipmitool sol activate`: `~.` closes the console, `~B` sends a serial break, `~?` lists the sequences, `~~` sends a `~`. `--escape <char>` changes the escape character (one printable ASCII character), `--no-escape` disables the sequences (for binary transfers); the end of the input then closes the console.
- **Every keystroke goes to the BMC**, Ctrl+C included, without local echo (the remote console echoes, or hides a password), so arrow keys, function keys and BIOS setup screens work; `~.` is the way out. On Linux and macOS, the terminal is switched with `stty raw -echo` on `/dev/tty` and restored when the console closes, on an error, and from a shutdown hook (a kill). On Windows, where Java cannot switch the console to raw mode, a PowerShell child reads the keys of the console (`[Console]::ReadKey`) and hands them over, the arrow, editing and function keys as their ANSI sequences; use Windows Terminal (the default since Windows 11) for the escape sequences of the remote console to be interpreted. Ctrl+C is a key for the BMC there too, and the Windows console stops treating it as a signal while the console is open: `~.` is the way out, and Ctrl+Break ends the program through the shutdown hook. When neither works, the console falls back to line mode: the input is sent when Enter is pressed, without local echo.
- When stdin is not a terminal, its bytes are forwarded as they come and the end of the input closes the console, so `printf 'root\r' | ipmicli ... sol` works in scripts. Each read of the input is one write to the BMC: a keystroke in raw mode, a line or a block from a pipe, sent as one SOL packet or several when it exceeds the payload size of the BMC. With `-v`, the CLI sums the console up when it closes: writes and bytes sent, the mean acknowledgement time per write, bytes received.
- When the BMC deactivates the console (another user activated SOL, or the session was lost), the CLI says so on stderr and exits with 70. When SOL is active in another session the BMC still has, the activation fails with `The SOL payload is in use by another session: instance 1 by session ... (user ID 2, privilege 4)`, exit 70: the CLI never deactivates the console of a live session. A console ended by a kill is deactivated by the shutdown hook; one ended by a hard kill is not, and some BMCs (Supermicro) keep its payload active for good: once the BMC has forgotten that dead session, within a minute, the next `sol` deactivates the stale payload itself and goes on.

The default privilege of `sol` is Administrator, which most BMCs require to activate the SOL payload; `-L user` or `-L operator` is enough on the BMCs that allow it. The SOL console shares the session of the client, so the `--timeout` bounds its setup only: an idle console never times out. See [Serial over LAN](serial-over-lan.html) for what the BMCs do.

## Exit codes

The sysexits values of the MetricsHub command-line clients:

| Code | Meaning |
| --- | --- |
| `0` | Success (including `sol` closed with `~.` or by the end of the input). |
| `1` | Partial result: `fru` could not read some FRUs completely (reported on stderr); the rest was printed. |
| `64` | Invalid usage, including an unreadable password or key file, and a setting the client refuses (a cipher suite without integrity, a password longer than 20 bytes). |
| `66` | `fru <id>`: no such FRU. |
| `69` | BMC unreachable: unknown host, socket error, no reply to the session setup (wrong host, UDP port 623 filtered, IPMI over LAN disabled). |
| `70` | IPMI failure: an error completion code (also in the reply to `raw`), no common cipher suite, a BMC without IPMI 2.0 (RMCP+), a malformed reply, the SOL console deactivated by the BMC. |
| `74` | Local I/O failure (stdout closed). |
| `77` | Authentication or authorization failure: unknown user, wrong password or BMC key, privilege level refused at login, insufficient privilege (`D4h`, with the `-L` hint). |
| `124` | Timeout: the deadline of the subcommand expired, or a message of the session got no reply after all the tries. |
| `127` | The launcher of the [installer](installation.html#command-line-client) found no Java 8 or later (install one from [Adoptium](https://adoptium.net), or set `IPMICLI_JAVA_HOME`), or no jar (run the installer again). |

The mapping follows the [exceptions](timeouts-and-errors.html#exceptions) of the client: `IpmiConnectionException` 69, `IpmiAuthenticationException` 77, `IpmiTimeoutException` 124, `IpmiCompletionCodeException` 70 (77 for `D4h`), any other `IpmiClientException` 70.

```text
$ ipmicli -h bmc.example.com -u monitor -p wrong chassis; echo $?
ipmicli: The BMC bmc.example.com refused the login of monitor: wrong password or BMC key (Authentication check failed)
77
$ ipmicli -h 192.0.2.1 -u monitor -pf pw.txt chassis; echo $?
ipmicli: No reply from 192.0.2.1:623 to the session setup after 4 tries: wrong host, UDP port 623 filtered, or IPMI over LAN disabled (Command timed out)
69
```

## Examples

What a BMC offers, before any login:

```bash
ipmicli -h bmc.example.com probe
```

The power state, reading the password from a file:

```bash
ipmicli -h bmc.example.com -u monitor -pf pw.txt power status
```

Which BMC this is (manufacturer, product, firmware), as JSON for a script:

```bash
ipmicli -h bmc.example.com -u monitor -pf pw.txt info --json
```

Power a server on, then make it blink its identify LED for a minute, with an account allowed the Operator level:

```bash
ipmicli -h bmc.example.com -u operator -pf pw.txt power on
ipmicli -h bmc.example.com -u operator -pf pw.txt identify 60
```

The temperatures and fans of a BMC that requires a BMC key, with the time of each step:

```bash
ipmicli -h bmc.example.com -u monitor -pf pw.txt -kf kg.txt -v sensors --type Temperature,Fan
```

Every sensor as JSON Lines, filtered with `jq`:

```bash
ipmicli -h bmc.example.com -u monitor -pf pw.txt sensors --json | jq -r 'select(.status != "OK") | .name'
```

The system board FRU of a BMC that only offers cipher suite 3, on another port:

```bash
ipmicli -h bmc.example.com -P 6230 -u monitor -pf pw.txt -C 3 fru 0
```

The events logged since entry 643, the last one of the previous run:

```bash
ipmicli -h bmc.example.com -u monitor -pf pw.txt sel --since 643
```

A console on the serial port, closed with `~.`:

```bash
ipmicli -h bmc.example.com -u admin -pf pw.txt sol
```

The DCMI capabilities of a BMC, with a raw request:

```bash
ipmicli -h bmc.example.com -u admin -pf pw.txt raw 0x2c 0x01 0xdc 0x01
```

## ipmitool equivalents

| ipmitool | ipmicli |
| --- | --- |
| `ipmitool -I lanplus -H h -U u -P p mc info` (or `bmc info`) | `ipmicli -h h -u u -p p info` (the manufacturer as its IANA number, not a name) |
| `ipmitool -I lanplus ... chassis status` | `ipmicli ... chassis` |
| `ipmitool -I lanplus ... chassis power status` | `ipmicli ... power status` |
| `ipmitool -I lanplus ... chassis power on` (and `off`, `cycle`, `reset`, `soft`, `diag`) | `ipmicli ... power on` (same actions; the session is opened at the Operator level, not Administrator) |
| `ipmitool -I lanplus ... chassis identify [<seconds>]`, `chassis identify force` | `ipmicli ... identify [<seconds>]`, `identify force`, `identify off` (`chassis identify 0` in ipmitool) |
| `ipmitool -I lanplus ... sdr list` or `sensor list` | `ipmicli ... sensors` (`--long` for the thresholds) |
| `ipmitool -I lanplus ... sdr type Temperature` | `ipmicli ... sensors --type Temperature` |
| `ipmitool -I lanplus ... fru print` | `ipmicli ... fru` |
| `ipmitool -I lanplus ... sel list` or `sel elist` | `ipmicli ... sel` (the sensor numbers, not the names) |
| `ipmitool -I lanplus ... sel info` | `ipmicli ... -v sel` (on stderr) |
| `ipmitool -I lanplus ... sol activate` | `ipmicli ... sol` |
| `ipmitool -I lanplus ... raw 0x06 0x01` | `ipmicli ... raw 0x06 0x01` (every byte hexadecimal, `0x` or not, where `ipmitool` reads `10` as decimal and `010` as octal; no leading space before the bytes; an error completion code exits with 70, 77 for `D4h`, and the message on stderr; odd network functions are refused) |
| `ipmitool -I lanplus ... lan print` (the cipher suites) | `ipmicli -h h probe` (no login needed) |
| `-I lanplus` | Implied: the CLI speaks RMCP+ (IPMI 2.0) only. |
| `-H host` | `-h host` |
| `-U user` | `-u user` |
| `-P password` | `-p password` |
| `-f file` (password file) | `-pf file` |
| `-p port` | `-P port` |
| `-k kg` (BMC key as text), `-y hexkg` | `-k hexkg` (hexadecimal only) |
| `-L USER` | The default of every read subcommand; `-L operator` or `-L administrator` to raise it. |
| `-C 3` | `-C 3` |
| `-N seconds`, `-R retries` | `--message-timeout <ms>`, `--retries <n>` |
| `-v` | `-v` (the connection details and the time of each step, on stderr) |
| `~.` to close `sol activate` | `~.` |

`ipmitool` prints a sensor reading as `na` when the BMC reports it unavailable: `ipmicli` prints `unavailable` in the `Status` column and leaves `Reading` empty.