IPMI Java Client 2.0.00
-
Home
- Getting Started
Command-Line Client
Every release ships a self-contained executable jar that bundles the library and a command-line client, ipmicli. This page is its manual. Install it with one command (Java 8 or later is required):
Linux / macOS
$ curl -fsSL https://metricshub.org/ipmi-java/get | sh
Windows (PowerShell)
irm https://metricshub.org/ipmi-java/get.ps1 | iex
The installer verifies the checksum of the jar and puts an ipmicli launcher on the PATH; see Installation[1] to inspect the script first, pin a version or change the directories.
ipmicli [options] <subcommand> [subcommand options]
Without the installer, download ipmi-java-2.0.00-standalone.jar from the latest release[2] and run it with java -jar ipmi-java-2.0.00-standalone.jar wherever this page says ipmicli. The jar needs no other file: the library has no dependency.
The CLI is a thin layer over the IpmiClient[3] API: every subcommand is one operation of the client, with the same defaults, the same session handling[4] and the same failures, reported as exit codes. It is meant to feel familiar to ipmitool users: see the ipmitool equivalents.
Synopsis
ipmicli -h <host> probe [--json]
ipmicli -h <host> -u <user> [options] info [--json]
ipmicli -h <host> -u <user> [options] chassis [--json]
ipmicli -h <host> -u <user> [options] power status | on | off | cycle | reset | soft | diag
ipmicli -h <host> -u <user> [options] identify [<seconds> | force | off]
ipmicli -h <host> -u <user> [options] sensors [--type <type>,...] [--name <glob>,...] [--long] [--json]
ipmicli -h <host> -u <user> [options] fru [<id>...] [--json]
ipmicli -h <host> -u <user> [options] sel [--since <id>] [--json]
ipmicli -h <host> -u <user> [options] sol [--escape <char> | --no-escape]
ipmicli -h <host> -u <user> [options] raw <netfn> <command> [<data byte>...] [--json]
ipmicli --help | --version
The options before the subcommand are the connection options; the options after it belong to the subcommand, in any order with its arguments. --help prints the usage summary, --version the version of the build.
Subcommands
| Subcommand | Library operation | Description |
|---|---|---|
probe |
capabilities() |
What the BMC offers before any login: IPMI 2.0 support, whether a BMC key (Kg) is required, the anonymous and null-user logins, per-message and user-level authentication, and the cipher suites with their algorithms, whether the library implements them, and the one the CLI would choose. Needs no credentials: the first thing to run when a login fails. |
info |
deviceId() |
The identity of the BMC: manufacturer and product IDs, firmware revision, IPMI version, the functions it provides (Device ID[5]). |
chassis |
chassisStatus() |
The power state, the power restore policy, the last power event, the faults (power, cooling, drive), interlock, overload, intrusion, front panel lockout, and the identify state. |
power status |
chassisStatus() |
Prints on or off. |
power on, off, cycle, reset, soft, diag |
chassisControl() |
Powers the system on; off at once; off then on; resets it; asks the operating system to shut down (ACPI); pulses a diagnostic interrupt (NMI). Prints nothing: the exit code says whether the BMC accepted the command, which it carries out afterwards. |
identify, identify <seconds>, identify force, identify off |
chassisIdentify() |
Blinks the identify LED of the chassis for 15 seconds, or for <seconds> (1 to 255), or until identify off with force (not every BMC supports it). Prints nothing. |
sensors |
sensors() |
One line per sensor with its reading, unit and status. --type and --name select the sensors before they are read (fewer round trips on a slow BMC); --long adds the sensor number, the entity, the six thresholds and the problem of a sensor without reading. |
fru |
frus() |
The FRU inventory, one block per FRU with the fields of its chassis, board and product areas; <id>... reads only these FRU IDs. |
sel |
sel() |
The System Event Log, one line per entry with its time, the sensor that reported it, the event and its direction; --since <id> reads only the entries after the given record ID. |
sol |
sol().open() |
An interactive Serial over LAN console on the serial port of the server. |
raw |
raw(netFn, command).data(...).execute() |
Sends any request, like ipmitool raw: the network function, the command and the data bytes in hexadecimal, 0x optional (06, 0x06 and 6 are the same byte). Prints the response data in hexadecimal, 16 bytes per line. Extension and OEM network functions are accepted (raw 0x2c 0x01 0xdc 0x01, Get DCMI Capabilities Info). |
sensors lists the sensor types to pass to --type as they are named in SensorType[6] (Temperature, Voltage, Fan, PowerSupply, Processor, Memory…), case-insensitively; --name takes globs where * matches any characters and ? one, case-insensitively, and either option can be repeated or given a comma-separated list.
Connection options
| Option | Description |
|---|---|
-h, --hostname <host> |
BMC host name or IP address (IPv4 or IPv6). Required. |
-u, --username <user> |
User name. Required, except for probe. An empty string (-u "") is the null user (anonymous login). |
-p, --password <password> |
Password. Command-line arguments may be visible to other local processes: avoid in automation. |
-pf, --password-file <file> |
Read the password from a UTF-8 file (preferred for automation, see below). |
-k, --bmc-key <hex> |
BMC key (Kg) of a two-key login, in hexadecimal (0x optional), at most 20 bytes. |
-kf, --bmc-key-file <file> |
Read the hexadecimal BMC key from a file. |
-P, --port <port> |
UDP port of the BMC. Default: 623. |
-L, --privilege <level> |
user, operator or administrator (case-insensitive). Default: the lowest level the subcommand needs (see below). |
-C, --cipher-suite <id>[,<id>...] |
One ID: use exactly this cipher suite, without discovery. Several: the preference order among the suites the BMC offers. Default: 17,3,8,16,2,7. Suites without integrity (0, 1, 6, 15) are refused: their replies could be forged. |
-t, --timeout <ms> |
Deadline of the subcommand, in milliseconds. Default: 120000. For sol, it bounds the session setup and the payload activation only. |
--message-timeout <ms> |
Per-message timeout. Default: 5000. |
--retries <n> |
Resends of a message that got no reply. Default: 3. |
-v, --verbose |
Print to stderr the address, the user and privilege, the cipher suite preference, and the time of each operation. Never prints a secret. |
--help |
Print the usage summary. |
--version |
Print the version of the build. |
The two password options are mutually exclusive, and so are the two BMC key options. Every option also takes the --option=value form. -p is the password and -P the port, as in the other MetricsHub command-line clients; ipmitool uses the reverse (see the equivalents).
Default privilege per subcommand
A session asks for its maximum privilege level at login and is raised to it right after, and a BMC refuses the login, or the raise, when the account is not allowed that level. So the CLI asks for the least privilege that works (unlike ipmitool, which asks for Administrator and fails with read-only accounts unless given -L USER):
| Subcommands | Default -L |
|---|---|
info, chassis, power status, sensors, fru, sel |
user |
power on, off, cycle, reset, soft, diag, identify |
operator |
sol, raw |
administrator |
A BMC that refuses a command at the session's level answers D4h: the CLI exits with 77 and says which higher -L to use (at the Administrator level, that the BMC restricts the command). Serial over LAN is the usual case: most BMCs activate the SOL payload at the Administrator level only, some at the User level. A raw request can be anything, so raw asks for Administrator, like ipmitool: give -L user to send a read with a read-only account.
Passwords and BMC key
If neither -p nor -pf is given (and the subcommand is not probe), the CLI asks the password on the interactive console, without echo. There is no console when the standard input or output is redirected (| jq, > out.txt): such runs must use --password-file (or, less securely, --password).
A password file is decoded as UTF-8 and exactly one final LF, CRLF or CR is removed; every other byte, spaces and earlier line endings included, is part of the password. The same rule applies to the BMC key file, which holds the key in hexadecimal. A password or key longer than the 20 bytes a BMC stores is refused before anything is sent.
Secrets are never printed: not in the usage errors, not with --verbose, not in the failure messages. The CLI blanks the password argument it was given and wipes its copies of the password and of the key when it ends.
Output
Diagnostics go only to stderr, so stdout can always be piped or parsed. The text output is meant for humans and is stable enough for grep; --json prints UTF-8 JSON Lines[7]: one object per sensor, FRU or SEL entry, one object for probe, info, chassis and raw. Absent values (a reading the sensor does not have, a threshold the record does not set, an empty FRU field) are omitted from the JSON objects, never printed as 0.
The output below was captured on a Lenovo RD350 (serial numbers masked), with ipmicli -h bmc.example.com -u monitor -pf pw.txt ....
probe
$ ipmicli -h bmc.example.com probe
IPMI 2.0 supported
BMC key (Kg) not required
Anonymous login disabled
Null user names disabled
Non-null user names enabled
Per-message authentication enabled
User-level authentication enabled
Cipher suites
ID Authentication Integrity Confidentiality Library
3 RAKP-HMAC-SHA1 HMAC-SHA1-96 AES-CBC-128 supported
17 RAKP-HMAC-SHA256 HMAC-SHA256-128 AES-CBC-128 supported
Chosen cipher suite 17
The last line is the suite a login with the same -C option would use: the first suite of the preference that the BMC offers, or the single suite of a one-ID -C, which is used without discovery. When that suite is one the library does not implement, or one the BMC does not offer, the line says so and that the login would fail; none means a login would fail with offers none of the cipher suites (Troubleshooting[8]). --json prints one object with the same fields and the suites as an array:
{"ipmi20":true,"bmcKeyRequired":false,"anonymousLogin":false,"nullUserNames":false,"nonNullUserNames":true,"perMessageAuthentication":true,"userLevelAuthentication":true,"cipherSuites":[{"id":3,"authentication":"RAKP-HMAC-SHA1","integrity":"HMAC-SHA1-96","confidentiality":"AES-CBC-128","supported":true},{"id":17,"authentication":"RAKP-HMAC-SHA256","integrity":"HMAC-SHA256-128","confidentiality":"AES-CBC-128","supported":true}],"chosenCipherSuite":17}
info
$ ipmicli -h bmc.example.com -u monitor -pf pw.txt info
Device ID 32
Device revision 1
Firmware revision 5.38
IPMI version 2.0
Manufacturer ID 19046
Product ID 502
Device available yes
Provides device SDRs no
Functions SENSOR_DEVICE, SDR_REPOSITORY_DEVICE, SEL_DEVICE, FRU_INVENTORY_DEVICE, IPMB_EVENT_RECEIVER, IPMB_EVENT_GENERATOR, CHASSIS_DEVICE
Aux firmware revision b2010000
The values are those of DeviceId[5]: the manufacturer ID is the IANA enterprise number of the vendor (19046 is Lenovo), the firmware revision is printed as ipmitool prints it, the functions are the DeviceFunction[9] names (none when the BMC flags none), and the Aux firmware revision line (four bytes in hexadecimal, vendor-defined) is only printed by a BMC that sends it.
{"id":32,"revision":1,"firmwareRevision":"5.38","ipmiVersion":"2.0","manufacturerId":19046,"productId":502,"available":true,"providesDeviceSdrs":false,"functions":["SENSOR_DEVICE","SDR_REPOSITORY_DEVICE","SEL_DEVICE","FRU_INVENTORY_DEVICE","IPMB_EVENT_RECEIVER","IPMB_EVENT_GENERATOR","CHASSIS_DEVICE"],"auxiliaryFirmwareRevision":"b2010000"}
chassis and power status
$ ipmicli -h bmc.example.com -u monitor -pf pw.txt chassis
Power on
Power restore policy PowerRestored
Last power events AC_FAILED
Power fault no
Power overload no
Interlock no
Power control fault no
Cooling fault no
Drive fault no
Intrusion no
Front panel lockout no
Identify Off
The values are those of ChassisStatus[10]: the power restore policy is PoweredOff, PowerRestored, PoweredUp or Unknown, the last power events are AC_FAILED, POWER_OVERLOAD, INTERLOCK, POWER_FAULT and IPMI_COMMAND (none when the BMC reports none), and the Identify line is only printed by a BMC that reports the identify state.
{"powerOn":true,"powerRestorePolicy":"PowerRestored","lastPowerEvents":["AC_FAILED"],"powerFault":false,"powerOverload":false,"interlock":false,"powerControlFault":false,"coolingFault":false,"driveFault":false,"intrusion":false,"frontPanelLockout":false,"identifyState":"Off"}
power status prints just on or off.
power actions and identify
$ ipmicli -h bmc.example.com -u operator -pf pw.txt power off; echo $?
0
$ ipmicli -h bmc.example.com -u operator -pf pw.txt power status
off
A power action and identify print nothing: the exit code is 0 once the BMC has accepted the command. The BMC carries it out afterwards (a power off takes a few seconds, a soft shutdown as long as the operating system needs): power status shows the result. The actions map to the PowerCommand[11] of the library: on is PowerUp, off is PowerDown (immediate, no operating system shutdown), cycle is PowerCycle (off for at least a second, then on), reset is HardReset, soft is SoftShutdown and diag is DiagnosticInterrupt. cycle of a system that is off is refused by the client before anything is sent (exit code 70: some BMCs would power the system up), reset of a system that is off by most BMCs with D5h (exit code 70); cycle, soft and diag are optional in the specification, and a BMC that does not implement them answers CCh. An action is sent once, never again when its reply is lost (the BMC may have carried it out): a lost reply exits with 124, and power status tells what the BMC did.
identify blinks the identify LED for 15 seconds, identify 60 for a minute (1 to 255), and identify force until identify off, on the BMCs that implement the “force identify on” option (the others answer CCh). chassis shows the identify state on the BMCs that report it.
sensors
$ ipmicli -h bmc.example.com -u monitor -pf pw.txt sensors
Name Type Reading Unit Status
Ambient Temp Temperature 19 DegreesC ok
CPU1 DTS Temperature -42 DegreesC ok
Exhaust Temp Temperature 22 DegreesC ok
Host Power PowerUnit ok
System Power Current 88 Watts ok
Fan 1 Fan 6700 Rpm ok
HDD DriveBay unavailable
PSU Redundancy PowerSupply Fully Redundant
System 3.3V Voltage 3.38 Volts ok
PSU1 Present PowerSupply Presence detected
(An excerpt: the Lenovo card has 49 sensors.) The columns are aligned on their widest value, two spaces apart. The Reading is the converted reading of a threshold sensor, rounded to three decimals, in the Unit of its record; a discrete sensor has no reading. Status is the status()[12] of a threshold sensor against its thresholds (ok, non-critical, critical, non-recoverable), the asserted states of a discrete sensor (Presence detected, Fully Redundant…), or unavailable when the BMC reports no valid reading (a sensor that is not scanned, not present, or whose reading the BMC refused).
--long adds the sensor number, the entity, the six thresholds (lower and upper non-recoverable, critical and non-critical) and, for a sensor without reading, the reason:
$ ipmicli -h bmc.example.com -u monitor -pf pw.txt sensors --type temperature --long
Name Number Type Entity Reading Unit Status LNR LC LNC UNC UC UNR Problem
Ambient Temp 1 Temperature AirInlet 1 19 DegreesC ok 3 8 37 39
CPU1 DTS 2 Temperature Processor 1 -42 DegreesC ok
CPU2 DTS 3 Temperature Processor 2 -46 DegreesC ok
Exhaust Temp 9 Temperature SystemChassis 1 22 DegreesC ok
With --json, one object per sensor, with the fields of Sensor[12] (reading and rawReading only when the reading is valid, the thresholds only when the record sets them, problem only when there is one):
$ ipmicli -h bmc.example.com -u monitor -pf pw.txt sensors --type Fan --name 'Fan 1' --json
{"name":"Fan 1","number":122,"type":"Fan","entity":"Fan","entityInstance":1,"unit":"Rpm","reading":6600.0,"rawReading":66,"status":"OK","states":[],"lowerCritical":1600.0}
An SDR record the library cannot decode is reported on stderr (ipmicli: SDR record 0006h (type 0Bh): ...) and the other sensors are printed: see Sensors or FRUs are missing[13].
fru
$ ipmicli -h bmc.example.com -u monitor -pf pw.txt fru
FRU 0: MotherBoard FRU (SystemBoard 1)
Chassis type RackMountChassis
Board manufacturer LENOVO
Board product RD350-RD450
Board serial number 8SSB20A05892R1SH4AY0000
Board part number SB20A05892
Board mfg date 2014-10-31T04:59:00Z
Board custom 5 00:8C:FA:00:00:00
Product manufacturer LENOVO
Product name RD350
Product part/model number 00000000000001
Product version 70D60001EA
Product serial number S4M00000
FRU 3: MidPlane FRU (OtherSystemBoard 1)
FRU 17: PSU1 FRU (SystemInternalExpansionBoard 2)
Product manufacturer LITEON
Product name PS-2451-6L-LF
Product serial number 003W
ipmicli: FRU 3: Cannot read FRU 3: ReadFruData failed: Requested Sensor, data, or record not present. (completion code CBh)
(An excerpt.) One block per FRU, headed by its ID, its name and its entity from the SDR locator record, then the fields of its chassis, board and product areas that are not empty (the custom fields of an area numbered as the area lists them, a binary one in hexadecimal). The board manufacturing date is UTC, ISO-8601. A FRU the BMC cannot read completely is reported on stderr with the fields read so far, and fru exits with 1 once every FRU is printed; a FRU that is declared but absent (an empty power supply bay, FRU 3 above) is the usual case (Troubleshooting[13]).
fru 0 17 reads only these FRUs; an ID that no locator record declares exits with 66 (ipmicli: no such FRU 9). --json prints one object per FRU, with the summary fields of Fru[14] (manufacturer, model, serialNumber, partNumber) and one nested object per area:
{"id":17,"name":"PSU1 FRU","entity":"SystemInternalExpansionBoard","entityInstance":2,"manufacturer":"LITEON","model":"PS-2451-6L-LF","serialNumber":"003W","product":{"manufacturerName":"LITEON","productName":"PS-2451-6L-LF","serialNumber":"003W"},"complete":true}
An incomplete FRU has "complete":false and a problems array.
sel
$ ipmicli -h bmc.example.com -u monitor -pf pw.txt sel
ID Time Type Sensor Event Direction
1 2024-05-15T09:15:25Z EventLoggingDisabled 254 Log area reset/cleared assertion
2 2024-05-15T09:16:11Z OemTimestamped OEM data 02 01 05 00 00 00
3 2024-05-15T09:16:11Z OemTimestamped OEM data 02 08 05 00 00 00
5 2024-05-15T09:23:27Z PowerUnit 100 Power off/down assertion
6 2024-05-15T09:23:34Z PowerUnit 100 Power off/down deassertion
7 2024-05-15T09:24:15Z VersionChange 0 Firmware or software incompatibility detected assertion
640 pre-init 315532807s PowerSupply 219 Presence detected assertion
643 pre-init 315532815s PowerSupply 156 Fully Redundant assertion
(An excerpt: the Lenovo card has 643 entries, 358 of them OEM records.) One line per entry of the System Event Log[15], in the order of the log: the record ID, the time (UTC, ISO-8601; pre-init <seconds> for an event logged before the BMC had the time, like the Pre-Init of ipmitool; empty for an OEM entry without timestamp), the sensor type of a system event or the record type of an OEM one, the sensor number, the event in the wording of ipmiutil (of ipmitool for the few events ipmiutil does not name) or the OEM bytes, and assertion or deassertion. The times are UTC whatever the BMC keeps (it reports the offset of a local SEL time with Get SEL Time UTC Offset). -v adds to stderr what Get SEL Info says of the log: its number of entries, the time of the last addition and erase, and that offset.
--since <id> prints only the entries after the given record ID, the ID of the last entry of a previous run (the whole log when the BMC does not hold that entry any more, as after a clear; a log cleared and filled up to that ID again goes unnoticed: the lastErase time of -v tells); the header alone means no new entry. --json prints one object per entry with the fields of SelEntry[16]: timestamp only when it is a date, preInitSeconds only for a pre-init one, the system event fields (sensorType, sensorNumber, generatorId, eventType, event, direction, eventData in hexadecimal) only for a system event, manufacturerId and oemData only for an OEM entry:
$ ipmicli -h bmc.example.com -u monitor -pf pw.txt sel --since 5 --json
{"id":6,"type":"System","timestamp":"2024-05-15T09:23:34Z","sensorType":"PowerUnit","sensorNumber":100,"generatorId":32,"eventType":111,"event":"PowerOffOrDown","description":"Power off/down","direction":"Deassertion","eventData":"00ffff"}
{"id":7,"type":"System","timestamp":"2024-05-15T09:24:15Z","sensorType":"VersionChange","sensorNumber":0,"generatorId":1,"eventType":111,"event":"FirmwareOrSoftwareIncompatibilityDetected","description":"Firmware or software incompatibility detected","direction":"Assertion","eventData":"830800"}
{"id":8,"type":"OemTimestamped","timestamp":"2024-05-15T09:29:39Z","description":"OEM data 02 01 05 05 00 00","manufacturerId":19046,"oemData":"020105050000"}
The sensor names are not resolved: join sensorNumber with the number of sensors --json when you need them (ipmitool sel elist walks the SDR repository for that, which takes as long as sensors on a slow BMC).
raw
$ ipmicli -h bmc.example.com -u admin -pf pw.txt raw 0x2c 0x01 0xdc 0x01
dc 01 05 02 00 01 07
$ ipmicli -h bmc.example.com -u admin -pf pw.txt raw 0x06 0x01
20 01 05 38 02 bf 66 4a 00 f6 01 b2 01 00 00
The response data, after the completion code, in hexadecimal: 16 bytes per line, nothing for a reply without data. The first request is Get DCMI Capabilities Info (Group Extension network function 2Ch, whose first data byte is the defining body, DCh for DCMI): the reply says DCMI 1.5. The second is Get Device ID, the command behind info.
Every byte is hexadecimal, 0x or not: 10 is 10h, where ipmitool reads 10 as decimal and 010 as octal. The network function must be one of a request: an even byte from 00 to 3e (the odd ones are those of the responses, IPMI 2.0 section 5.1), the standard ones as well as Transport (0c), Group Extension (2c), OEM/Group (2e) and the controller-specific OEM ones (30 to 3e). An error completion code is printed on stderr with the exit code 70 (77 with the -L hint for D4h), after the data the BMC may have sent with it; it is not retried, a busy c0 or a c3 included. Like any message, the request is sent again when its reply is lost (--retries 0 sends it once): a power command is better sent with power, which has the safeguards. --json prints one object, with the completion code as a number and the data in hexadecimal (omitted when empty), also for an error completion code:
{"completionCode":0,"data":"dc010502000107"}
Interactive SOL console
ipmicli -h bmc.example.com -u admin -pf pw.txt sol
sol activates the Serial over LAN payload and bridges it with the terminal until the console is closed. The bytes of the BMC go to stdout unmodified, so the local terminal interprets the escape sequences of the remote console; the typed bytes go to the BMC.
- Escape sequences, recognized at the start of a line, as with
sshandipmitool sol activate:~.closes the console,~Bsends a serial break,~?lists the sequences,~~sends a~.--escape <char>changes the escape character (one printable ASCII character),--no-escapedisables the sequences (for binary transfers); the end of the input then closes the console. - Every keystroke goes to the BMC, Ctrl+C included, without local echo (the remote console echoes, or hides a password), so arrow keys, function keys and BIOS setup screens work;
~.is the way out. On Linux and macOS, the terminal is switched withstty raw -echoon/dev/ttyand restored when the console closes, on an error, and from a shutdown hook (a kill). On Windows, where Java cannot switch the console to raw mode, a PowerShell child reads the keys of the console ([Console]::ReadKey) and hands them over, the arrow, editing and function keys as their ANSI sequences; use Windows Terminal (the default since Windows 11) for the escape sequences of the remote console to be interpreted. Ctrl+C is a key for the BMC there too, and the Windows console stops treating it as a signal while the console is open:~.is the way out, and Ctrl+Break ends the program through the shutdown hook. When neither works, the console falls back to line mode: the input is sent when Enter is pressed, without local echo. - When stdin is not a terminal, its bytes are forwarded as they come and the end of the input closes the console, so
printf 'root\r' | ipmicli ... solworks in scripts. Each read of the input is one write to the BMC: a keystroke in raw mode, a line or a block from a pipe, sent as one SOL packet or several when it exceeds the payload size of the BMC. With-v, the CLI sums the console up when it closes: writes and bytes sent, the mean acknowledgement time per write, bytes received. - When the BMC deactivates the console (another user activated SOL, or the session was lost), the CLI says so on stderr and exits with 70. When SOL is active in another session the BMC still has, the activation fails with
The SOL payload is in use by another session: instance 1 by session ... (user ID 2, privilege 4), exit 70: the CLI never deactivates the console of a live session. A console ended by a kill is deactivated by the shutdown hook; one ended by a hard kill is not, and some BMCs (Supermicro) keep its payload active for good: once the BMC has forgotten that dead session, within a minute, the nextsoldeactivates the stale payload itself and goes on.
The default privilege of sol is Administrator, which most BMCs require to activate the SOL payload; -L user or -L operator is enough on the BMCs that allow it. The SOL console shares the session of the client, so the --timeout bounds its setup only: an idle console never times out. See Serial over LAN[17] for what the BMCs do.
Exit codes
The sysexits values of the MetricsHub command-line clients:
| Code | Meaning |
|---|---|
0 |
Success (including sol closed with ~. or by the end of the input). |
1 |
Partial result: fru could not read some FRUs completely (reported on stderr); the rest was printed. |
64 |
Invalid usage, including an unreadable password or key file, and a setting the client refuses (a cipher suite without integrity, a password longer than 20 bytes). |
66 |
fru <id>: no such FRU. |
69 |
BMC unreachable: unknown host, socket error, no reply to the session setup (wrong host, UDP port 623 filtered, IPMI over LAN disabled). |
70 |
IPMI failure: an error completion code (also in the reply to raw), no common cipher suite, a BMC without IPMI 2.0 (RMCP+), a malformed reply, the SOL console deactivated by the BMC. |
74 |
Local I/O failure (stdout closed). |
77 |
Authentication or authorization failure: unknown user, wrong password or BMC key, privilege level refused at login, insufficient privilege (D4h, with the -L hint). |
124 |
Timeout: the deadline of the subcommand expired, or a message of the session got no reply after all the tries. |
127 |
The launcher of the installer[1] found no Java 8 or later (install one from Adoptium[18], or set IPMICLI_JAVA_HOME), or no jar (run the installer again). |
The mapping follows the exceptions[19] of the client: IpmiConnectionException 69, IpmiAuthenticationException 77, IpmiTimeoutException 124, IpmiCompletionCodeException 70 (77 for D4h), any other IpmiClientException 70.
$ ipmicli -h bmc.example.com -u monitor -p wrong chassis; echo $?
ipmicli: The BMC bmc.example.com refused the login of monitor: wrong password or BMC key (Authentication check failed)
77
$ ipmicli -h 192.0.2.1 -u monitor -pf pw.txt chassis; echo $?
ipmicli: No reply from 192.0.2.1:623 to the session setup after 4 tries: wrong host, UDP port 623 filtered, or IPMI over LAN disabled (Command timed out)
69
Examples
What a BMC offers, before any login:
ipmicli -h bmc.example.com probe
The power state, reading the password from a file:
ipmicli -h bmc.example.com -u monitor -pf pw.txt power status
Which BMC this is (manufacturer, product, firmware), as JSON for a script:
ipmicli -h bmc.example.com -u monitor -pf pw.txt info --json
Power a server on, then make it blink its identify LED for a minute, with an account allowed the Operator level:
ipmicli -h bmc.example.com -u operator -pf pw.txt power on
ipmicli -h bmc.example.com -u operator -pf pw.txt identify 60
The temperatures and fans of a BMC that requires a BMC key, with the time of each step:
ipmicli -h bmc.example.com -u monitor -pf pw.txt -kf kg.txt -v sensors --type Temperature,Fan
Every sensor as JSON Lines, filtered with jq:
ipmicli -h bmc.example.com -u monitor -pf pw.txt sensors --json | jq -r 'select(.status != "OK") | .name'
The system board FRU of a BMC that only offers cipher suite 3, on another port:
ipmicli -h bmc.example.com -P 6230 -u monitor -pf pw.txt -C 3 fru 0
The events logged since entry 643, the last one of the previous run:
ipmicli -h bmc.example.com -u monitor -pf pw.txt sel --since 643
A console on the serial port, closed with ~.:
ipmicli -h bmc.example.com -u admin -pf pw.txt sol
The DCMI capabilities of a BMC, with a raw request:
ipmicli -h bmc.example.com -u admin -pf pw.txt raw 0x2c 0x01 0xdc 0x01
ipmitool equivalents
| ipmitool | ipmicli |
|---|---|
ipmitool -I lanplus -H h -U u -P p mc info (or bmc info) |
ipmicli -h h -u u -p p info (the manufacturer as its IANA number, not a name) |
ipmitool -I lanplus ... chassis status |
ipmicli ... chassis |
ipmitool -I lanplus ... chassis power status |
ipmicli ... power status |
ipmitool -I lanplus ... chassis power on (and off, cycle, reset, soft, diag) |
ipmicli ... power on (same actions; the session is opened at the Operator level, not Administrator) |
ipmitool -I lanplus ... chassis identify [<seconds>], chassis identify force |
ipmicli ... identify [<seconds>], identify force, identify off (chassis identify 0 in ipmitool) |
ipmitool -I lanplus ... sdr list or sensor list |
ipmicli ... sensors (--long for the thresholds) |
ipmitool -I lanplus ... sdr type Temperature |
ipmicli ... sensors --type Temperature |
ipmitool -I lanplus ... fru print |
ipmicli ... fru |
ipmitool -I lanplus ... sel list or sel elist |
ipmicli ... sel (the sensor numbers, not the names) |
ipmitool -I lanplus ... sel info |
ipmicli ... -v sel (on stderr) |
ipmitool -I lanplus ... sol activate |
ipmicli ... sol |
ipmitool -I lanplus ... raw 0x06 0x01 |
ipmicli ... raw 0x06 0x01 (every byte hexadecimal, 0x or not, where ipmitool reads 10 as decimal and 010 as octal; no leading space before the bytes; an error completion code exits with 70, 77 for D4h, and the message on stderr; odd network functions are refused) |
ipmitool -I lanplus ... lan print (the cipher suites) |
ipmicli -h h probe (no login needed) |
-I lanplus |
Implied: the CLI speaks RMCP+ (IPMI 2.0) only. |
-H host |
-h host |
-U user |
-u user |
-P password |
-p password |
-f file (password file) |
-pf file |
-p port |
-P port |
-k kg (BMC key as text), -y hexkg |
-k hexkg (hexadecimal only) |
-L USER |
The default of every read subcommand; -L operator or -L administrator to raise it. |
-C 3 |
-C 3 |
-N seconds, -R retries |
--message-timeout <ms>, --retries <n> |
-v |
-v (the connection details and the time of each step, on stderr) |
~. to close sol activate |
~. |
ipmitool prints a sensor reading as na when the BMC reports it unavailable: ipmicli prints unavailable in the Status column and leaves Reading empty.
- [1] installation.html#command-line-client
- [2] https://github.com/metricshub/ipmi-java/releases/latest
- [3] index.html#quick-start
- [4] timeouts-and-errors.html#session-recovery
- [5] device-id.html
- [6] apidocs/org/metricshub/ipmi/core/coding/commands/sdr/record/SensorType.html
- [7] https://jsonlines.org/
- [8] troubleshooting.html#ipmiclientexception-3a-the-bmc-offers-none-of-the-cipher-suites
- [9] apidocs/org/metricshub/ipmi/client/DeviceFunction.html
- [10] chassis-status.html
- [11] chassis-status.html#controlling-the-power
- [12] sensors.html#the-sensor-object
- [13] troubleshooting.html#sensors-or-frus-are-missing
- [14] fru-inventory.html
- [15] system-event-log.html
- [16] system-event-log.html#the-selentry-object
- [17] serial-over-lan.html
- [18] https://adoptium.net
- [19] timeouts-and-errors.html#exceptions