IPMI Java Client 2.0.00
-
Home
- Usage
System Event Log
The BMC logs the hardware events it sees in its System Event Log (SEL): a threshold crossed, a power supply that lost its input, a memory error, a chassis intrusion, a power-off. It is the main source of hardware alerts on IPMI: the sensors say what the state is now, the log says what happened. The client reads it entry by entry.
try (IpmiClient bmc = IpmiClient.builder(host).credentials(user, password).build()) {
for (SelEntry entry : bmc.sel().execute()) {
System.out.println(entry);
}
}
SEL entry 1 at 2024-05-15T09:15:25Z: EventLoggingDisabled sensor 254, Log area reset/cleared (assertion)
SEL entry 2 at 2024-05-15T09:16:11Z: OemTimestamped of manufacturer 19046, OEM data 02 01 05 00 00 00
SEL entry 5 at 2024-05-15T09:23:27Z: PowerUnit sensor 100, Power off/down (assertion)
SEL entry 6 at 2024-05-15T09:23:34Z: PowerUnit sensor 100, Power off/down (deassertion)
SEL entry 7 at 2024-05-15T09:24:15Z: VersionChange sensor 0, Firmware or software incompatibility detected (assertion)
How the log is read
sel().execute()[1]:
- sends Get SEL Time UTC Offset, for a BMC that keeps its SEL time as local time (IPMI 2.0 revision 1.1; a BMC without the command keeps it in UTC), and Get SEL Info, for the number of entries and the time of the last addition and erase (an empty log is not read: Get SEL Entry fails on it);
- sends Get SEL Entry for the first entry (record ID
0000h), then for the next record ID each reply gives, until that ID isFFFFh. Each entry is read whole, so no reservation is needed (IPMI 2.0, section 31.5); when a BMC asks for one anyway, or cancels the one it gave (C5h), the client takes a reservation with Reserve SEL and reads the entry again.
The first entry read (or the entry given to since(), when nothing follows it) is read again after the walk, and so is Get SEL Info: when the log was erased meanwhile (its erase timestamp changed, after a Clear SEL or a Delete SEL Entry, whose record IDs may be reused; or the first entry is another one, as two erases within a second leave the timestamp unchanged), or when an entry named as the next one is not there any more (CBh), the read starts over, once, whole (the entry given to since() may be another one by then) and from what the log is now; a log that changes twice during a read fails it with IpmiClientException rather than return a list that mixes two logs, and so does a log whose next record IDs loop or that answers another entry than the one asked for. While a Clear SEL is in progress (81h), the read waits for its end, up to 10 s. A BMC without Get SEL Info (C1h, D5h) is read all the same, without the counts and timestamps; any other refusal of it fails the read, as a clear could then go unnoticed.
Every record type is decoded: the system events, the OEM records with and without timestamp, and the reserved types, of which only the record ID is defined (Supported Commands[2]). A log of 643 entries takes about 20 s on a Lenovo IMM (one round trip per entry); a Supermicro BMC answers its 18 entries in half a second.
The read needs the User privilege, like the other read operations, and is retried once[3] on a new session when the session is lost while it runs.
The SelEntry object
Each SelEntry[4] is immutable and holds:
| Method | Content |
|---|---|
id() |
The record ID, 1 to 65534, unique until the log is cleared |
type() |
SelRecordType[5]: System for a system event, OemTimestamped (C0h–DFh), OemNonTimestamped (E0h–FFh) or Reserved |
timestamp() |
When the event was logged (Optional<Instant>), for a system event or a timestamped OEM entry whose timestamp is a date (below) |
preInitSeconds() |
For an event logged before the BMC had the time: the seconds since the initialization of the SEL device (OptionalLong) |
sensorType() |
The SensorType[6] of the sensor that reported a system event (Temperature, PowerSupply, Memory, PhysicalSecurity, …) |
sensorNumber() |
Its sensor number: the Sensor.number()[7] of the sensor in the SDR repository, unique for a given generatorId() |
generatorId() |
What logged the event: the slave address (0x20 for the BMC) or system software ID in the low byte, its channel and LUN in the high byte |
isFrom(sensor) |
Whether a Sensor[7] of the SDR repository is the one that reported the event: same owner (address or software ID, LUN) and same number |
eventType() |
The event/reading type code: 0x01 for a threshold event, 0x02–0x0C generic discrete, 0x6F sensor-specific, 0x70–0x7F OEM |
event() |
What happened, as the ReadingType[8] of the event offset: UpperCriticalGoingHigh, PowerSupplyInputLost, LogAreaReset, … |
direction() |
EventDirection[9]: Assertion (the threshold crossed, the failure detected) or Deassertion (back within the threshold, the failure gone) |
description() |
The event in the wording of ipmiutil, as Sensor.states()[10] (Failure detected, Log area reset/cleared, Power Supply AC lost; that of ipmitool for the OS Boot installation events of IPMI 2.0 revision 1.1, which ipmiutil does not name: Installation started), the name of the ReadingType spaced out when neither names it (Upper Critical Going High), or the event/reading type and offset when the specification does not name it (Unknown event type 08h offset 6h) |
eventData() |
The three event data bytes as the BMC sent them: the offset in the low nibble of the first; for a threshold event, the raw reading that triggered it and the threshold in the next two (below) |
manufacturerId(), oemData() |
The IANA enterprise number of a timestamped OEM entry, and the OEM bytes of an OEM entry (6 with a timestamp, 13 without) |
record() |
The decoded SelRecord[11], for everything else |
The accessors of a system event (sensorType(), event(), …) are empty for the OEM and reserved entries, and manufacturerId() and oemData() for the system events: type() tells which. Two entries are equals() when they are the same record (same ID, same 16 bytes).
SelEntryList[12], the result of execute(), is an unmodifiable List<SelEntry> that also gives what Get SEL Info says of the whole log: totalEntries(), lastAddition() and lastErase() (Optional: a BMC that never erased its log reports no erase time), and the utcOffsetMinutes() of the SEL time.
Timestamps
A SEL timestamp is a number of seconds since 1970, but not always: the values up to 20000000h (January 1987) stamp the events logged before the BMC had the time, counted from the initialization of the SEL device (IPMI 2.0, section 37.1), and FFFFFFFFh is an unspecified timestamp. timestamp() is empty in both cases; preInitSeconds() gives the former, like the Pre-Init of ipmitool. A Lenovo IMM logs the events of its first boot with its clock at 1980, which falls in that range: they are reported as preInitSeconds() of about 315 million.
A BMC that keeps its SEL time as local time says so with the Get SEL Time UTC Offset command of IPMI 2.0 revision 1.1, and the client subtracts that offset from every timestamp it returns, so that timestamp(), lastAddition() and lastErase() are UTC instants; utcOffsetMinutes() gives the offset applied: 0 when the BMC does not implement the command (C1h, D5h) or leaves the offset unspecified (07FFh, as after a Set SEL Time), while any other refusal (D4h…) fails the read, as the timestamps would be off by an unknown offset. The offset is the one in force when the log is read: the log records none per entry, so an entry logged under another offset (before a daylight saving change, or a change of the time zone of the BMC) comes out shifted by the difference, an hour usually. The timestamps are still only as good as the clock of the BMC: of the BMCs tested, a Supermicro keeps UTC, a Lenovo IMM reports an offset of 60 minutes, and a Dell iDRAC runs its SEL clock on the local time of its time zone setting without implementing the command, so its timestamps come out two hours ahead of UTC in summer and nothing in the protocol says so. Compare the SEL time of the BMC (ipmitool sel time get) with the wall clock when the hour of an event matters.
Threshold events
A threshold event (eventType() = 0x01) says which threshold was crossed in which direction (UpperCriticalGoingHigh, LowerNonCriticalGoingLow, …), and its eventData() usually carries the raw reading that triggered it (second byte) and the threshold (third byte), as the high bits of the first byte announce (01 in bits 7:6 for the reading, 01 in bits 5:4 for the threshold). They are raw bytes: convert them with the calcFormula() of the sensor's FullSensorRecord[13], found among bmc.sensors().execute() with isFrom(sensor): a sensor number is unique for its owner only (the BMC, a satellite controller, the BIOS…), so isFrom() matches the generatorId() of the event (the address or software ID and the LUN of what logged it) with the owner of the SDR record, and the sensor number, as ipmitool sel elist does:
SensorList sensors = bmc.sensors().execute();
for (SelEntry entry : bmc.sel().execute()) {
if (entry.eventType().orElse(0) == 0x01 && entry.direction().get() == EventDirection.Assertion) {
byte[] data = entry.eventData();
for (Sensor sensor : sensors) {
if (entry.isFrom(sensor) && (data[0] & 0xC0) == 0x40 && sensor.record() instanceof FullSensorRecord) {
FullSensorRecord record = (FullSensorRecord) sensor.record();
System.out.println(entry.timestamp().orElse(null) + " " + sensor.name() + ": " + entry.description()
+ " at " + record.calcFormula(data[1] & 0xFF) + " " + sensor.unit());
}
}
}
}
OEM entries
Vendors log a lot in their own format: of the 643 entries of a Lenovo IMM, 358 are timestamped OEM records (manufacturer 19046, Lenovo). They are returned with their timestamp, manufacturer ID and six bytes, which only the vendor documents; the system events among the OEM entries are reported like the others. A system event of an OEM sensor type (C0h–FFh) or OEM event/reading type (70h–7Fh) has event() = UnknownOEMEvent and a description() that gives the codes.
Polling for new entries
Reading the whole log at every poll costs one round trip per entry. since(entry) reads only the entries added after the given one, the last entry of the previous read: that entry is read again to find the next one and left out.
SelEntry lastSeen = null;
while (true) {
SelEntryList entries = lastSeen == null ? bmc.sel().execute() : bmc.sel().since(lastSeen).execute();
for (SelEntry entry : entries) {
alert(entry);
lastSeen = entry;
}
Thread.sleep(60_000);
}
When the log was cleared since, the record IDs started over: the BMC holds another entry under the ID of the last one seen, or none, and the whole log is read (lastErase() is then more recent than the previous read). since(int recordId) does the same with the ID alone, for a cursor kept across restarts, but cannot tell a log cleared and filled up to that ID again from the one it read before: compare lastErase() with the previous read when using it.
The log has a fixed capacity (hundreds to a few thousand entries); when it is full, most BMCs stop logging (SelFull, SelAlmostFull events of the EventLoggingDisabled sensor type announce it) and the log must be cleared with ipmitool sel clear, the web interface of the BMC, or the Clear SEL command, which the library does not implement.
With the command-line client
$ ipmicli -h bmc.example.com -u monitor -pf pw.txt sel
ID Time Type Sensor Event Direction
1 2023-03-15T17:06:39Z EventLoggingDisabled 114 Log area reset/cleared assertion
2 pre-init 39s PowerSupply 101 Power Supply AC lost assertion
3 pre-init 44s PowerSupply 101 Power Supply AC lost deassertion
4 2023-04-03T09:35:31Z OsBoot 0 Installation started assertion
5 2024-03-28T15:20:37Z PowerSupply 100 Power Supply AC lost assertion
6 2024-03-28T15:20:37Z PowerSupply 116 Redundancy Lost assertion
7 2024-03-28T15:20:42Z PowerSupply 100 Power Supply AC lost deassertion
(The first entries of a Dell iDRAC.) See sel[14] in the manual of the command-line client: --since <id> and --json.
- [1] apidocs/org/metricshub/ipmi/client/SelRequest.html
- [2] supported-commands.html#sel-records
- [3] timeouts-and-errors.html#session-recovery
- [4] apidocs/org/metricshub/ipmi/client/SelEntry.html
- [5] apidocs/org/metricshub/ipmi/core/coding/commands/sel/SelRecordType.html
- [6] apidocs/org/metricshub/ipmi/core/coding/commands/sdr/record/SensorType.html
- [7] sensors.html#the-sensor-object
- [8] apidocs/org/metricshub/ipmi/core/coding/commands/sdr/record/ReadingType.html
- [9] apidocs/org/metricshub/ipmi/core/coding/commands/sel/EventDirection.html
- [10] sensors.html#states
- [11] apidocs/org/metricshub/ipmi/core/coding/commands/sel/SelRecord.html
- [12] apidocs/org/metricshub/ipmi/client/SelEntryList.html
- [13] apidocs/org/metricshub/ipmi/core/coding/commands/sdr/record/FullSensorRecord.html
- [14] cli.html#sel