- First steps
- IpmiConnectionException: No reply from ...
- IpmiTimeoutException
- IpmiAuthenticationException
- IpmiCompletionCodeException with InsufficentPrivilege (D4h)
- IpmiClientException: The BMC ... does not support IPMI 2.0 / RMCP+ ...
- IpmiClientException: The BMC ... offers none of the cipher suites ...
- Sensors or FRUs are missing
- Collecting is slow
- Closing a Serial over LAN console fails with Message timed out
- Equivalent ipmitool and ipmiutil commands
IPMI Java Client 2.0.00
-
Home
- Reference
Troubleshooting
First steps
- Run
ipmicli probefrom the same machine, with the standalone jar (Command-Line Client[1]): it needs no credentials and no session, and says whether the BMC answers, whether it requires a BMC key, and which cipher suites it offers that the library implements. Thenipmicli -v chassiswith the account: a single command, so it tests the credentials, the privilege level and the cipher suite in a few hundred milliseconds, and its exit code (77 authentication, 69 unreachable, 124 timeout) and message name the cause. In code, the same two steps arecapabilities()andchassisStatus(). - Check the BMC from the same machine with another tool, with the same account, privilege level and cipher suite (see below). If
ipmitooloripmiutilfails too, the problem is in the BMC configuration or the network: see Preparing the BMC[2]. - Act on the exception type: the library never logs; every failure is an
IpmiClientException[3] whose subclass and message say what went wrong, and every problem that did not fail the operation is in its result (Problems that do not fail the operation[4]).
IpmiConnectionException: No reply from ...
The BMC did not answer the session setup after all the tries (4 tries of 5 s by default, about 20 s).
| Cause | Check |
|---|---|
| Wrong address: the server's operating system instead of its BMC | The BMC has its own IP address (ipmitool lan print 1 on the server). |
| IPMI over LAN disabled on the BMC | Enabling IPMI over LAN[5] |
| UDP port 623 filtered | Firewall[6] |
An IPMI 1.5-only BMC, with cipherSuite(id) (-C with one ID) |
Without the cipher suite discovery, the client does not ask the BMC which IPMI versions it supports, and an IPMI 1.5-only BMC never answers the RMCP+ Open Session. With the discovery, it fails at once (below). |
| Several sessions to the same BMC at the same time | BMCs drop replies under concurrent sessions: use one client per BMC, which serializes its operations[7]. |
IpmiTimeoutException
Either the deadline of the operation expired (... did not complete within ...): a large SDR repository or many FRUs on a slow BMC, a network that loses many replies, or a deadline shorter than the handshake tries; raise the timeout[8], 2 minutes by default. Or a message of the session got no reply after all its tries (No reply from ... to ... after 4 tries: the session is lost): the BMC rebooted, expired or revoked the session, or drops replies under load; the next operation opens a new session, and a read operation is retried once[9] on it by itself.
A lost UDP reply is retried after the message timeout[10]; an operation only fails when every try in a row gets no reply.
IpmiAuthenticationException
The RAKP handshake (the login) failed, or the BMC refused to raise the session to the requested privilege right after it (80h, 81h: a BMC that is busy then is an IpmiClientException), and the session could not be opened. The credentials are sent once; statusCode() says why:
statusCode() |
Meaning |
|---|---|
null (... wrong password or BMC key (Authentication check failed)) |
The BMC's proof does not match the password: wrong password (or wrong BMC key[11]). |
UnauthorizedName |
Unknown user, or a user not allowed to log in over the LAN channel. |
UnauthorizedRole, InvalidRole, InsufficentPrivilege |
The account is not allowed the requested privilege level[12] on the LAN channel. |
Unknown (... refused the Operator privilege to <user>: the level exceeds the privilege limit of the channel or of the user (completion code 81h), or 80h, the level is not available for this user) |
The login worked, but the account, the LAN channel or the cipher suite (Cipher Suite Priv Max in ipmitool lan print 1) is limited to a lower level, and the BMC refused to raise the session (Set Session Privilege Level). Request a lower privilege[12] (-L with ipmicli), or allow the level to the account. |
InvalidIntegrityCheckValue |
The BMC rejected the integrity check value of RAKP Message 3: wrong password or BMC key on a BMC that checks it first. |
An IllegalArgumentException from build() (Password is too long. ..., Username is too long. ..., BMC key is too long. ...) means the password or the BMC key is longer than the 20 bytes a BMC stores, or the user name longer than 16 bytes: the BMC cannot have it, and nothing is sent to it. An IpmiClientException: ... does not match the request (Open Session Response, RAKP Message 2, RAKP Message 4) means a handshake reply of the BMC is for another session, or confirms other algorithms than the requested ones; it is not sent again.
Check the account with ipmitool -I lanplus ... -L USER chassis status: ipmitool reports RAKP 2 HMAC is invalid for a wrong password and unauthorized name for an unknown user.
IpmiCompletionCodeException with InsufficentPrivilege (D4h)
The BMC refused a command at the session's privilege level, which the client requests at login and sets right after it: the command needs a higher level than the requested one. The default User level is enough for everything the client reads; send() of a control command (Chassis Control, chassis identify) needs privilege(PrivilegeLevel.Operator) on the builder, and Serial over LAN Administrator on most BMCs. If a BMC refuses a read command at the User level, check:
- the privilege of the account on the LAN channel (
ipmitool channel getaccess 1 <user id>), - the maximum privilege of the cipher suite in use (
Cipher Suite Priv Maxinipmitool lan print 1).
When commands that worked earlier in the same session start failing with D4h, the session was revoked, and sending the command again in the same session does not help. On HP iLO 5, this is what happens when another client deletes the sessions, for example a management tool logged in as an administrator; the revocation shows at a whole minute of the session's age (60 s, 120 s, …). Close the client and open a new one, or wait for the next operation: a session whose messages get no reply is reopened, but one that answers D4h is not.
IpmiClientException: The BMC ... does not support IPMI 2.0 / RMCP+ ...
Before any RMCP+ request, the client sends Get Channel Authentication Capabilities in the IPMI v1.5 format, which every BMC answers (IPMI 2.0, section 13.13), and its reply reports no IPMI v2.0 connections (table 22-15): the BMC is IPMI 1.5-only (MD2, MD5 or straight password authentication), or IPMI 2.0 is disabled on its LAN channel. The client only opens RMCP+ sessions (What this client needs[13]), like ipmitool -I lanplus, which refuses such a BMC too (“This BMC does not support IPMI v2 / RMCP+”). ipmicli probe exits with 70 the same way.
IpmiClientException: The BMC ... offers none of the cipher suites ...
The client only opens sessions with a cipher suite whose messages are signed (How IpmiClient chooses the suite[14]), and the message lists the suites the BMC offers. Enable suite 17 or 3 on the BMC (in its web interface, or with ipmitool lan set 1 cipher_privs), or list the suites the BMC offers with cipherSuites() on the builder, among those the library implements.
With the low-level API[15], a suite that uses an algorithm the client does not implement fails with IllegalArgumentException: Confidentiality algorithm XRC4-128 is not yet implemented. (or MD5-128 integrity): choose a suite whose isSupported() is true.
Sensors or FRUs are missing
| Symptom | Cause |
|---|---|
skippedRecords() lists a record |
A record that cannot be decoded is skipped with its reason; the other sensors are still returned. SDR records[16] lists what is decoded. |
Sensor.problem() says Get Sensor Reading failed: ... |
The BMC refused the Get Sensor Reading of that sensor with an error completion code: the sensor is returned without reading or states, and the other sensors are still returned. With D4h, the BMC may have revoked the session (see the D4h section above). |
Fru.problems() says FRU <id> is truncated at offset <n>: ... Requested Sensor, data, or record not present |
The FRU is declared in the SDR repository but not present, for example an empty power supply bay. Usually harmless: the reading stops there and the areas read so far are decoded. |
Fru.problems() says Cannot read FRU <id> or Cannot decode FRU <id> |
The BMC refused Get FRU Inventory Area Info for that FRU, or its data is not in the IPMI FRU format (for example the SPD data of a memory module, #107[17]). The other FRUs are still returned. |
Fru.problems() says The <area> info area at offset <n> is truncated |
The read stopped before the end of that area (see above): the complete areas of the FRU are still returned. |
A sensor known to ipmitool is not returned |
Only Full and Compact sensor records of the BMC's own repository are read: sensors behind satellite controllers are not (#84[18]), and shared Compact records are not expanded (#100[19]). A sensor whose reading the BMC flags as unavailable or not scanned (ipmitool shows na or disabled) is returned without reading or states, with problem() set. |
Negative processor temperatures (CPU1 DTS = -44.0) |
Not an error: Intel Digital Thermal Sensor readings are the margin below the maximum junction temperature. |
Collecting is slow
- FRUs: each FRU is read 16 bytes at a time, one round trip per chunk: a few seconds per FRU on some BMCs (#102[20]).
- Lost replies stall an operation until the message timeout: shorten it (Timeouts and Errors[10]).
- Unselected sensors still cost a round trip each unless they are excluded with
types()ornames()[21].
Closing a Serial over LAN console fails with Message timed out
SerialOverLan.close() throws IOException caused by ConnectionException: Message timed out when the BMC does not answer Deactivate Payload within the tries of the message timeout[10]; the SolConsole[22] of the client swallows it and reports the console deactivated. The console still closes the sessions it opened.
We saw it on a Dell iDRAC whose server did not read its serial port: after characters were written to the console, the BMC answered nothing, from any session, for about 30 s. Open a new console or session after that delay.
Equivalent ipmitool and ipmiutil commands
With ipmitool, add -I lanplus -H <bmc> -U <user> -P <password> -L USER -C <suite>; with ipmiutil, add -N <bmc> -U <user> -P <password> -F lan2 -J <suite> -V 2.
| Library | ipmitool |
ipmiutil |
|---|---|---|
capabilities() |
channel getciphers ipmi |
|
chassisStatus() |
chassis status |
health |
frus().execute() |
fru print |
fru |
sensors().execute() |
sdr elist |
sensor |
sel().execute() |
sel info, sel elist |
sel |
sol().open() |
sol activate |
sol -a |
The state descriptions of Sensor.states()[23] follow the wording of ipmiutil.
ipmiutil sensor reads the sensors with Get Device SDR, which some BMCs refuse (D4h) at any privilege level, while this library reads the SDR repository with Get SDR. A failure of ipmiutil sensor alone does not mean the library will fail.
- [1] cli.html
- [2] preparing-the-bmc.html
- [3] timeouts-and-errors.html#exceptions
- [4] timeouts-and-errors.html#problems-that-do-not-fail-the-operation
- [5] preparing-the-bmc.html#enabling-ipmi-over-lan
- [6] preparing-the-bmc.html#firewall
- [7] configuration.html#thread-safety
- [8] configuration.html#timeout
- [9] timeouts-and-errors.html#session-recovery
- [10] timeouts-and-errors.html#message-timeout-and-retries
- [11] configuration.html#bmc-key
- [12] configuration.html#privilege-level
- [13] preparing-the-bmc.html#what-this-client-needs
- [14] preparing-the-bmc.html#how-ipmiclient-chooses-the-suite
- [15] low-level-api.html#choosing-the-cipher-suite
- [16] supported-commands.html#sdr-records
- [17] https://github.com/metricshub/ipmi-java/issues/107
- [18] https://github.com/metricshub/ipmi-java/issues/84
- [19] https://github.com/metricshub/ipmi-java/issues/100
- [20] https://github.com/metricshub/ipmi-java/issues/102
- [21] sensors.html#selecting-sensors
- [22] serial-over-lan.html#with-ipmiclient
- [23] sensors.html#states